Typhoon with EP-SH-N anti-static bar

The airknife is constructed of extruded aluminium with incorporated mounting grooves. This design provides a precise air volume over the entire width of the airknife. In the airkife tube a high air pressure appears and is flowing out of the airknife narrow outflow opening. The anti-static bar produces positive and negative ions which are blown onto the surface by the airknife. The electrons will now be exchanged, which causes the surface to be neutralised and the impurities to be removed. For use in hazardous zones, the Typhoon with the P-Sh-N-Ex anti-static bar is approved.

Airpressure sensor
Each Typhoon system is supplied with an airpressure sensor wich can measure the air pressure inside the airknife. If the pressure drops under the required level, the system does not work optimal. A system check is then neccessary, often it appears that the air filter needs to be cleaned.

Power unit A2A7M
Typhoon systems with EP-Sh-N anti-static bars incorporate a power unit type A2A7M. This unit contains an additional 12V power source for connection of the airpressure sensor.

  • Working distance up to 2000 mm
  • Surface cleaning
  • Low operational cost
  • Low noise
  • Working distance 2000 mm max.
  • Working width on demand
  • Housing material aluminum
  • Ionizing bar material PVC
  • Emitter pin special alloy
  • Cable metal shielded
  • Weight 4 kg/m
  • Ambient temperature 0 - 55 °C
  • Use circumstances industrial
  • Operating voltage 7 kV AC
  • Air connection 75 mm Ø
  • Suitable power unit A2A7S/ A2A7M/ MPM
  • Approval UL